Borri · Leonardo Plus RT
Borri Leonardo Plus RT 6000 VA
Online double-conversion UPS of 6–10 kVA that can be rack-mounted or stand as a tower. For networks, servers and small data centres.
6000 VArating
6000 Wnominal power
(4U)176 × 680 × 440 mmW × D × H
60 kgweight
- Online double conversion
- Reversible display
- Additional battery cabinets for longer autonomy
Price on requestModel: Leonardo Plus RT 6000 VA
Technical data
| Rating (VA) | 6000* |
| Nominal power (W) | 6000 |
| UPS dimensions WxDxH (mm) | (4U)176x680x440 |
| UPS weight (kg) | 60 |
Input
| Connection type | Hardwired 2w / Hardwired 3w (rectifier, bypass, neutral) |
| Nominal voltage | 230 Vac 1-phase |
| Voltage range | 170 to 288 Vac at full load |
| Frequency and range | 50/60 Hz, 45 to 65 Hz |
| Power factor | 0.99 |
| Current distortion (THDi) | <3% |
Output
| Connection type | Hardwired 2w, 8 IEC C13, 2 IEC C19 / Hardwired 2w |
| Nominal voltage | 230 Vac +/-1% 1-phase |
| Frequency | 50/60 Hz |
| Power factor | 1 |
| Overload capability | 105% continuous, 120% for 30 seconds, 150% for 160 milliseconds |
| Mode of operation | On-line, Eco-mode |
| Classification by IEC/EN 62040-3 | VFI-SS-11 |
Battery
| Autonomy time internal battery (min) | 50% load / 8 / External battery |
| 100% load | 5 |
Connectivity and function extensions
| Front panel | Display LCD, status LED, function keys |
| Communication | Included: USB, EPO, RS232. Optional: dry contact card, SNMP card, Modbus protocol Compatible platforms: Windows, Linux |
Environmental
| Operating temperature range | 0°C to +40°C |
| Altitude (AMSL) | <1000 m without power reduction, > 1000 m with reduction of 1% per 100 m |
| Audible noise at 1 m (dBA) | <50 |
Standards and certifications
| Quality assurance, environment, health and safety | ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007 |
| Safety | IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 |
| Test and performance | IEC/EN 62040-3 |



Borri · Leonardo Plus RT
Borri Leonardo Plus RT 6000 VA
Online double-conversion UPS of 6–10 kVA that can be rack-mounted or stand as a tower. For networks, servers and small data centres.
6000 VArating
6000 Wnominal power
(2U)88 × 680 × 440 mmW × D × H
25 kgweight
- Online double conversion
- Reversible display
- Additional battery cabinets for longer autonomy
Price on requestModel: Leonardo Plus RT 6000 VA
Technical data
| Rating (VA) | 6000** |
| Nominal power (W) | 6000 |
| UPS dimensions WxDxH (mm) | (2U)88x680x440 |
| Battery cabinet dimensions WxDxH (mm) | (2U)88x680x440 |
| UPS weight (kg) | 25 |
Input
| Connection type | Hardwired 2w / Hardwired 3w (rectifier, bypass, neutral) |
| Nominal voltage | 230 Vac 1-phase |
| Voltage range | 170 to 288 Vac at full load |
| Frequency and range | 50/60 Hz, 45 to 65 Hz |
| Power factor | 0.99 |
| Current distortion (THDi) | <3% |
Output
| Connection type | Hardwired 2w, 8 IEC C13, 2 IEC C19 / Hardwired 2w |
| Nominal voltage | 230 Vac +/-1% 1-phase |
| Frequency | 50/60 Hz |
| Power factor | 1 |
| Overload capability | 105% continuous, 120% for 30 seconds, 150% for 160 milliseconds |
| Mode of operation | On-line, Eco-mode |
| Classification by IEC/EN 62040-3 | VFI-SS-11 |
Battery
| Autonomy time internal battery (min) | 50% load / 8 / External battery |
| 100% load | External battery |
Connectivity and function extensions
| Front panel | Display LCD, status LED, function keys |
| Communication | Included: USB, EPO, RS232. Optional: dry contact card, SNMP card, Modbus protocol Compatible platforms: Windows, Linux |
Environmental
| Operating temperature range | 0°C to +40°C |
| Altitude (AMSL) | <1000 m without power reduction, > 1000 m with reduction of 1% per 100 m |
| Audible noise at 1 m (dBA) | <50 |
Standards and certifications
| Quality assurance, environment, health and safety | ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007 |
| Safety | IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 |
| Test and performance | IEC/EN 62040-3 |



Borri · Leonardo Plus RT
Borri Leonardo Plus RT 10000 VA
Online double-conversion UPS of 6–10 kVA that can be rack-mounted or stand as a tower. For networks, servers and small data centres.
10000 VArating
10000 Wnominal power
(3U)132 × 680 × 440 mmW × D × H
26 kgweight
- Online double conversion
- Reversible display
- Additional battery cabinets for longer autonomy
Price on requestModel: Leonardo Plus RT 10000 VA
Technical data
| Rating (VA) | 10000** |
| Nominal power (W) | 10000 |
| UPS dimensions WxDxH (mm) | (3U)132x680x440 |
| Battery cabinet dimensions WxDxH (mm) | (3U)132x680x440 |
| UPS weight (kg) | 26 |
Input
| Connection type | Hardwired 2w / Hardwired 3w (rectifier, bypass, neutral) |
| Nominal voltage | 230 Vac 1-phase |
| Voltage range | 170 to 288 Vac at full load |
| Frequency and range | 50/60 Hz, 45 to 65 Hz |
| Power factor | 0.99 |
| Current distortion (THDi) | <3% |
Output
| Connection type | Hardwired 2w, 8 IEC C13, 2 IEC C19 / Hardwired 2w |
| Nominal voltage | 230 Vac +/-1% 1-phase |
| Frequency | 50/60 Hz |
| Power factor | 1 |
| Overload capability | 105% continuous, 120% for 30 seconds, 150% for 160 milliseconds |
| Mode of operation | On-line, Eco-mode |
| Classification by IEC/EN 62040-3 | VFI-SS-11 |
Battery
| Autonomy time internal battery (min) | 50% load / 8 / External battery |
| 100% load | External battery |
Connectivity and function extensions
| Front panel | Display LCD, status LED, function keys |
| Communication | Included: USB, EPO, RS232. Optional: dry contact card, SNMP card, Modbus protocol Compatible platforms: Windows, Linux |
Environmental
| Operating temperature range | 0°C to +40°C |
| Altitude (AMSL) | <1000 m without power reduction, > 1000 m with reduction of 1% per 100 m |
| Audible noise at 1 m (dBA) | <50 |
Standards and certifications
| Quality assurance, environment, health and safety | ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007 |
| Safety | IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 |
| Test and performance | IEC/EN 62040-3 |
Other models of Leonardo Plus RT